InjuryDetector
DE/EN

Built on a scientific foundation

Movement pattern analysis is an established research field. We make transparent what our approach builds on — and invite scientists and practitioners to expand the collection with us.

Our position

Detect deviations from a movement baseline — not diagnose injuries out of nowhere

The most defensible scientific positioning is not "we diagnose injuries from two foot sensors" but: we detect clinically and athletically relevant deviations from the individual movement baseline, quantify risk and recovery signatures, and support medical decisions longitudinally. That is exactly what today’s literature robustly supports — and it does not preclude tightly validated injury modules later.

📏

Robustly measured KPIs

Gait speed, cadence, step/stride length, step time and variability, double-support ratio, step width, turning metrics and left-right asymmetry.

🏗

Technologically layered

Optical marker systems remain the reference standard; IMU wearables provide real-world reach; markerless video closes the gap for spatiotemporal parameters.

📉

Trajectory, not snapshot

Research is shifting from one-off tests to thresholds for clinically meaningful change over time — exactly our product’s logic.

Literaturverzeichnis

Curated study map — categorised by method

Not a claim to a complete systematic review, but the decision-relevant evidence: robust methods to measure movement change. Legend: Peer-reviewed Preprint Project/report

Reviews & methodology

Frame the feasibility window: what do which systems measure, and why do standardised parameter definitions matter?

  • Sy, N. et al. — Wearable inertial sensors for gait analysis: a technology overview Peer-Reviewed

    Journal of Spine Surgery, 2022

    Describes IMUs (accelerometer + gyroscope + magnetometer), derivation of orientation/position and the core trade-off "few sensors vs. high biomechanical resolution". Base source for realistically framing technical feasibility.

  • Review: standardised parameter definitions & validation in movement analysis Peer-Reviewed

    PMC (National Library of Medicine)

    Emphasises that changes only remain robustly comparable across time points, systems and studies if parameters are standardised and validated — a core requirement for our data ontology.

Lab-based gait analysis

Methodologically cleanest: optoelectronic multi-camera systems plus force plates as the gold standard.

  • Jerome, G. J. et al. — Gait characteristics associated with walking speed decline in older adults (Baltimore Longitudinal Study of Aging) Peer-Reviewed

    Archives of Gerontology and Geriatrics, 2015

    3D motion capture + force plates, multi-year follow-up: 23% showed a clinically relevant speed decline over ~3.2 years; longer strides and higher cadence were associated with lower risk. Proves that simple spatiotemporal metrics carry prospective, longitudinal relevance.

  • Biomechanical analysis of gait patterns in healthy individuals Peer-Reviewed

    Longdom (Open Access)

    Measures gait cycles three-dimensionally with optoelectronic systems and force plates — provides the healthy-movement reference values against which deviations are measured.

Sensor-based long-term & real-life monitoring

The strongest bridge between lab and product: wearable IMUs capture movement in daily life over days to years.

  • Real-life gait assessment in degenerative cerebellar ataxia: 2-year longitudinal study with body-worn IMUs Peer-Reviewed

    PubMed, 2025 · PMID 40395207

    Three body-worn IMUs under real walking conditions: variability measures (compound measure SPCmp) detect significant change after just one year — before clinical scales respond. High test-retest reliability (ICC ≥ 0.82).

  • Gait Variability as a Potential Motor Marker of Cerebellar Disease Peer-Reviewed

    Sensors (MDPI), 2024

    Investigates the relationship between variability of stride, arm swing and trunk movement and walking speed — shows which variability measures work as early markers.

  • Raykov, Y. P. et al. — Probabilistic modelling of free-living gait segments (Parkinson) Preprint

    Preprint, 2020 · 25 Parkinson-Patienten + 25 Kontrollen

    Addresses the real everyday problem: robust localisation of meaningful walking segments in unstructured data (sensor positions wrist/ankle/pocket/lower back). Central for a product outside standardised lab tests. As a preprint, to be weighted more cautiously.

  • Rinderknecht, M. D. et al. — MCIDs of digital gait measures in progressive multiple sclerosis Preprint

    Preprint, 2026 · 243 Personen, 96 Wochen

    Daily smartphone-based two-minute walk tests; derives minimal clinically important differences (MCIDs) for step velocity, duration and length. Shows the direction: away from the test date, toward thresholds for meaningful change. Preprint.

Markerless video & AI analysis

Pose estimation from 2D/3D video, compared against the optoelectronic gold standard — scalable and accessible.

  • Molteni, L. & Andreoni, G. — Validation of OpenPose against an optoelectronic system for lower-limb gait Peer-Reviewed

    Bioengineering (MDPI), 2025 · 20 Probanden (gesund & pathologisch)

    Spatiotemporal parameters with good-to-excellent ICCs; small absolute errors for cadence and mean speed; good agreement of range of motion in the sagittal plane. Evidence that markerless video is realistic for scalable spatiotemporal analytics.

  • Evaluation of markerless motion capture against gold-standard systems Peer-Reviewed

    Artificial Intelligence in Medicine (Elsevier), 2025

    Compares pose-estimation frameworks with optoelectronics; reports good-to-excellent agreement for spatiotemporal gait parameters, particularly in the sagittal plane.

  • Donahue, S. et al. — Uncertainty-calibrated multiview markerless gait analysis Preprint

    Preprint, 2026 · 68 Teilnehmende, 2 Institutionen

    Median errors of ~12-16 mm for step/stride length, bias-corrected kinematic errors of ~1.5-3.8°; plus calibrated estimation uncertainty. Shows where the stack can grow: not just estimate values, but state how certain they are. Preprint.

Clinical & translational projects

Funded projects translating the "norm-plus-deviation" logic into care — the strongest template for our product.

  • KIT — movement analysis for early osteoarthritis detection Research project

    Karlsruher Institut für Technologie (IfSS) & Sana Gelenkzentrum

    Models a catalogue of normal movement patterns and describes deviations probabilistically: restricted knee angle and slowed weight transfer become mathematically detectable early, before they are visually obvious. Exactly our logic — personal/population norm plus early measurable deviation.

  • AktiSmart-KI — Sensor-based activity and movement pattern recognition German MoH funded

    German Federal Ministry of Health — Digital Innovation / Smart Sensing

    Body-worn sensors recognise activities and movement patterns, detect falls, document treatment progress and derive treatment needs — reported activity recognition up to 85%. Shows the immediate value lies in trajectory data, early warning and decision support. Basis for our "Sensors for Seniors" use case.

Public health monitoring

Coarse population-level activity profiles — the outer layer of the problem, complementing the biomechanical depth layer.

  • RKI — HBSC analysis: physical activity of children and adolescents Institute/report

    Robert Koch-Institut (edoc)

    Works with macroscopic activity profiles (activity guidelines, sports activity, trends since 2009/10). Useful for public health questions — but injury detection requires finer, biomechanically interpretable signatures.

This collection is a curated selection of decision-relevant evidence, not a formal systematic review. Preprints are not yet peer-reviewed and should be weighted cautiously. All links lead to the original third-party sources.

Contribute

Know a relevant study? Suggest it.

We expand this directory together with scientists, physicians, coaches and the community. Every suggestion is reviewed by us before it is added.

Your input is stored solely to review the suggestion. Details in our privacy policy.